pyromation RAF185L88R484 Integral Transmitters
0
Description
The Water-Tight CIP RTD Assembly houses an optional integral Series 450 Temperature Transmitter (no connection head is required) that is ideal
for monitoring temperature in small areas such as tanks and pipes. The water-tight construction meets NEMA 6P requirements. Assemblies are
supplied with a surface finish that meets or exceeds 32µin Ra. Surface finishes of 15µin Ra or better are available upon request. Standard units
include a M12 process connection housing. The transmitter is a 2-wire unit with an analog output. It has measurement input for Pt100 resistance
thermometers (RTD) in 4-wire connections. Transmitters can be ranged from (-51 to 160) ºC [-60 to 320] ºF with a 10 ºC [18 ºF] minimum span
requirement. Ambient temperature limits for the M12 connector are (-40 to 85) °C